Reduced Odour Oil-Based Primer | Benjamin Moore
  • Reduced Odour Oil-Based Primer
Reduced Odour Oil-Based Primer. Item 1 of 1

Reduced Odour Oil-Based Primer

Insl-X

An alkyd primer/sealer formulated to produce lower odour levels compared to other Insl-X® alkyd primers.

See Product Details
  • Blocks stains
  • Quick drying
  • Excellent adhesion
  • Seals porous surfaces

Select Fulfilment Method

* Required

This item is currently unavailable.

This stain-blocking primer is effective at sealing water stains, tannin, nicotine stains and more.

  • For use on interior drywall, plaster, wood, masonry, acoustical tile, painted surfaces and wallpaper
  • Seals smoke stains on fire damaged walls
  • Can be used to spot prime exterior wood, shingles, and composition siding
  • Top-coat with alkyd or latex paints
Sub CategoryAlkyd
Key Feature(s)1 PartMulti-SubstrateOdor BlockingQuick DryingSealerSmoke CoverStain BlockingTintableTinted
Interior/ExteriorInterior
Recommended For Use OnCeiling Tile, Composite, Composite Wood, Concrete, Drywall, Masonite, Masonry, Plaster, Wood
SurfaceCeiling TileCompositeComposite WoodConcreteDrywallMasoniteMasonryPlasterWood
VOC Range< 400
VOC Range< 350
Compliance & CertificationsMPI 45
SpecificationsMPI 45
Coverage (Sq. Ft./Gal)30.2-39.5 sq.m. (325-425 sq. ft.)
Number of Recommended Coats1 or 2
Dry Time30 Minutes
Recoat Time2 Hours
Return to Service (Days)10
Resin Vehicle TypeAlkydOther
Clean UpMineral Spirits
Volume Solids (±2%)54.0
WFT: Wet Film Thickness (mils)3.7-5.0
DFT: Dry Film Thickness (mils)2.0-2.7
WPG (Weight per Gallon)6 kg (13.3 lbs.)
Application MethodBrushRollSpray
Application Temp Range (°F)7.2-32.2°C (45-90°F)
Application Spray Pressure (PSI)1500-3000
SegmentResidentialCommercial
ProjectBasementBathroomBedroomCeilingDoorKitchenLiving RoomTrim
Interior/ExteriorInterior
Sub CategoryAlkyd
Key Feature(s)1 PartMulti-SubstrateOdor BlockingQuick DryingSealerSmoke CoverStain BlockingTintableTinted
Recommended For Use OnCeiling Tile, Composite, Composite Wood, Concrete, Drywall, Masonite, Masonry, Plaster, Wood
SurfaceCeiling TileCompositeComposite WoodConcreteDrywallMasoniteMasonryPlasterWood
VOC Range< 400
VOC Range< 350
Compliance & CertificationsMPI 45
SpecificationsMPI 45
Coverage (Sq. Ft./Gal)30.2-39.5 sq.m. (325-425 sq. ft.)
Number of Recommended Coats1 or 2
Dry Time30 Minutes
Recoat Time2 Hours
Return to Service (Days)10
Resin Vehicle TypeAlkydOther
Clean UpMineral Spirits
Volume Solids (±2%)54.0
WFT: Wet Film Thickness (mils)3.7-5.0
DFT: Dry Film Thickness (mils)2.0-2.7
WPG (Weight per Gallon)6 kg (13.3 lbs.)
Application MethodBrushRollSpray
Application Temp Range (°F)7.2-32.2°C (45-90°F)
Application Spray Pressure (PSI)1500-3000
SegmentResidentialCommercial
ProjectBasementBathroomBedroomCeilingDoorKitchenLiving RoomTrim