Vapour Barrier Primer/Sealer | Benjamin Moore
  • Vapour Barrier Primer/Sealer
Vapour Barrier Primer/Sealer. Item 1 of 1

Vapour Barrier Primer/Sealer

Insl-X

Provides a film with low vapour permeability.

See Product Details
  • Provides a Class II vapour barrier
  • Low VOC
  • Offers good adhesion and hide
  • Excellent holdout

Select Fulfilment Method

* Required

This item is currently unavailable.

This fast-drying, nonbreathing primer-sealer acts as a moisture vapour barrier when applied on interior walls and ceilings.

  • For use on new or previously painted drywall construction, plaster, composition board, non-bleeding wood, and concrete
  • Perm rating of 0.58 when tested under ASTM D-1653
  • Class A (0-25) over non-combustible surfaces when tested in accordance with ASTM E-84
  • Can be used under latex or solvent-based paints
  • For commercial or residential applications
Key Feature(s)1 PartLow VOCMoisture BlockingMulti-SubstrateQuick DryingSealerSpatter ResistantTintableTinted
Interior/ExteriorInterior
Recommended For Use OnComposite, Composite Wood, Concrete, Masonry, Plaster, Wood, Drywall
SurfaceCompositeComposite WoodConcreteMasonryPlasterWoodDrywall
VOC Range< 50
Compliance & CertificationsMPI #61
Coverage (Sq. Ft./Gal)37.1-41.8 sq. m. (400-450 sq. ft.)
Number of Recommended Coats1
Dry Time1 Hour
Recoat Time2 Hours
Return to Service (Days)14
Resin Vehicle TypeAcrylicLatexWaterborneOther
Clean UpSoap and Water
Volume Solids (±2%)33.5
WFT: Wet Film Thickness (mils)3.6-4.0
DFT: Dry Film Thickness (mils)1.2-1.3
WPG (Weight per Gallon)4.9 kg (10.9 lbs)
Application MethodBrushRollSpray
Application Temp Range (°F)4.4-32.2 °C (40-90 °F)
Application Spray Pressure (PSI)1500-3000
SegmentResidentialCommercial
ProjectBasementBathroomBathroom CeilingBedroomCeilingGarageKitchenLiving RoomTrim
Recommended For Use OnComposite, Composite Wood, Concrete, Masonry, Plaster, Wood, Drywall
Key Feature(s)1 PartLow VOCMoisture BlockingMulti-SubstrateQuick DryingSealerSpatter ResistantTintableTinted
Interior/ExteriorInterior
SurfaceCompositeComposite WoodConcreteMasonryPlasterWoodDrywall
VOC Range< 50
Compliance & CertificationsMPI #61
Coverage (Sq. Ft./Gal)37.1-41.8 sq. m. (400-450 sq. ft.)
Number of Recommended Coats1
Dry Time1 Hour
Recoat Time2 Hours
Return to Service (Days)14
Resin Vehicle TypeAcrylicLatexWaterborneOther
Clean UpSoap and Water
Volume Solids (±2%)33.5
WFT: Wet Film Thickness (mils)3.6-4.0
DFT: Dry Film Thickness (mils)1.2-1.3
WPG (Weight per Gallon)4.9 kg (10.9 lbs)
Application MethodBrushRollSpray
Application Temp Range (°F)4.4-32.2 °C (40-90 °F)
Application Spray Pressure (PSI)1500-3000
SegmentResidentialCommercial
ProjectBasementBathroomBathroom CeilingBedroomCeilingGarageKitchenLiving RoomTrim